Samwha Eocr-fdm-500-s-220 Motor Protection Relay With Connector Cable 80C 300V
Samwha Eocr-fdm-500-s-220 Motor Protection Relay With Connector Cable 80C 300V
Samwha Eocr Ltd.
Shinhwa
Converter
Eocr-fdm
Eocr-fdm-500-s-220
Overcurrent Setting (Is): 0.1~800A
Undercurrent Setting: Less Than O.C Setting
Time Setting: Sw3
Start (D-time): Off, 1~200S
Trip (O-time): 0.2~30S 1~30S
Alert Setting: 50~100% Of Is
Power Supply: 85~250Vac/Dc, 50/60Hz
Output Relay:
Ol 2-spst
Al 1-spst
3A/250Vac Resistive
Trip Time:
Over-current: O-time In Greater Than Is
Phase Loss: Within 3S 1A (05 Type)
Phase Unbalance: 8S Deviation Greater Than 50%
Phase Reverse: 0.1S Rpr Sw. On
Locked Rotor: 0.5S 2~10 Times Of O.C
E97577
Awm 2464
Vw-1
80°C 300V
26Awg
Ll87299 Csa
Awm T2 80°C Ft1
Made In Korea
Weight: 310 Gm
Product Information
Product Information
Shipping & Returns
Shipping & Returns












Samwha Eocr-fdm-500-s-220 Motor Protection Relay With Connector Cable 80C 300V
Samwha Eocr-fdm-500-s-220 Motor Protection Relay With Connector Cable 80C 300V
Samwha Eocr-fdm-500-s-220 Motor Protection Relay With Connector Cable 80C 300V
Samwha Eocr Ltd.
Shinhwa
Converter
Eocr-fdm
Eocr-fdm-500-s-220
Overcurrent Setting (Is): 0.1~800A
Undercurrent Setting: Less Than O.C Setting
Time Setting: Sw3
Start (D-time): Off, 1~200S
Trip (O-time): 0.2~30S 1~30S
Alert Setting: 50~100% Of Is
Power Supply: 85~250Vac/Dc, 50/60Hz
Output Relay:
Ol 2-spst
Al 1-spst
3A/250Vac Resistive
Trip Time:
Over-current: O-time In Greater Than Is
Phase Loss: Within 3S 1A (05 Type)
Phase Unbalance: 8S Deviation Greater Than 50%
Phase Reverse: 0.1S Rpr Sw. On
Locked Rotor: 0.5S 2~10 Times Of O.C
E97577
Awm 2464
Vw-1
80°C 300V
26Awg
Ll87299 Csa
Awm T2 80°C Ft1
Made In Korea
Weight: 310 Gm
Original: $449.00
-70%$449.00
$134.70Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Samwha Eocr-fdm-500-s-220 Motor Protection Relay With Connector Cable 80C 300V
Samwha Eocr Ltd.
Shinhwa
Converter
Eocr-fdm
Eocr-fdm-500-s-220
Overcurrent Setting (Is): 0.1~800A
Undercurrent Setting: Less Than O.C Setting
Time Setting: Sw3
Start (D-time): Off, 1~200S
Trip (O-time): 0.2~30S 1~30S
Alert Setting: 50~100% Of Is
Power Supply: 85~250Vac/Dc, 50/60Hz
Output Relay:
Ol 2-spst
Al 1-spst
3A/250Vac Resistive
Trip Time:
Over-current: O-time In Greater Than Is
Phase Loss: Within 3S 1A (05 Type)
Phase Unbalance: 8S Deviation Greater Than 50%
Phase Reverse: 0.1S Rpr Sw. On
Locked Rotor: 0.5S 2~10 Times Of O.C
E97577
Awm 2464
Vw-1
80°C 300V
26Awg
Ll87299 Csa
Awm T2 80°C Ft1
Made In Korea
Weight: 310 Gm